Amigo A9000 Cardiac And Multi Parameter Patient Monitor

SKU AG-A9000-PM Category

Description

The A9000 Cardiac And Multi Parameter Patient Monitor is a low-end multiparameter patient monitor that can be used for bedside monitoring.

Features:

  • 12.1” high-resolution colour
  • TFT Display
  • LightWeight and Portable
  • Ideal for use in Post OP, Casualty and as Bedside Monitor
  • Huge Storage Facility for trend and Data of more than 720 hrs
  • Audible and Visual alarm with adjustable limits
  • Different interface to suit different clinical situations
  • Built-in Li-ion Battery
  • Description
  • Amigo Patient Monitor- A9000


Description:

  • 12.1” High-resolution Colour
  • TFT Display
  • LightWeight and Portable
  • Ideal for use in Post OP, Casualty and as Bedside Monitor
  • Huge Storage Facility for trend and Data of more than 720 hrs
  • Audible and Visual alarm with adjustable limits
  • Different interface to suit different clinical situations
  • Built-in Li-ion Battery
  • Upgradable to EtCO2 and IBP


Optional:
EtCO2, IBP, Masimo SPO2, Thermal Printer, Moving Cart / Wall Mount, Wireless network 12 V power supply, high energy battery


Specification:

  • ECG : Lead Mode : 1,11,111, AVR,aVL,aVF,
  • V Gain:0.25,0.50,1,2
  • Sweep Speed: 6.25, 12.5,25,and 50 mm/sec
  • HR Range: 15-300 BPM 
  • Calibration :+/-1mV Accuracy +/- 3 BPM 
  • Measurement Range: 0-50 Degree
  • Resolution : 0.1 Degree
  • Display : T1,T2,
  • Delta T Unit: Degree or Fahrenheit
  • Selectable Respiration Principle : RA-LL
  • Impedance Measurement Range: 0-156 BPM
  • Accuracy: +/-3 BPM
  • Resolution : 2BPM
  • SPO2 Display : Waveform and %
  • Value Measurement Range : 0-100%
  • Accuracy: 1% PR Range : 15-300
  • BPM Accuracy: +/-3BPM
  • Resolution : 1BPM 
  • EtCO2 ( Plug and Play ) Measurement Types: Sidestream/MicroStream/MainStream
  • Measurement Range : 0-19.7% , 0-150 mmHg, 0-20kPa
  • Accuracy: 0-40 mmHg +/-2 mmHg or +/-2%; 41-70mmHg +/- 5% 71-100 mmHg +/- 8% 100-150 mmHg +/-10% 
  • NIBP Principle : Oscillometric
  • Measurement Type : Adult, Pediatric, Neonatal
  • Measurement Method : Manual, Automatic,
  • STAT Unit: mmHg or kPa 
  • Accuracy: +/-10mmHg or +/-5% 
  • IBP Measurement Range :-10-300 mmHg
  • Number of Channels: single or dual channels selectable
  • Accuracy:+/-2mmHg or +/-2%
  • Pressure Tag: ART.CVP,RVP,LAP,RAP,PAP, ICP, LVP 
  • Temperature Number of Channels: 2 channel

Additional information

Brand

Amigo